Question 770
During fault isolation, the following is observed: The local user is absent from the user group referenced by the applicable policy. Operational symptom: A local account authenticates but is denied access to a firewall policy that requires a group. What is the most defensible root-cause assessment?
- The local account is administratively disabled.
- The FortiGate and RADIUS server no longer share the same secret.
- RADIUS group authorization attributes do not align with the FortiGate group mapping.
- Firewall policy identity-group membership does not include the authorized account.
- RADIUS transport is blocked or misrouted between FortiGate and the server.
Explanation
Correct Answer
D:The observed “The local user is absent from the user group referenced by the applicable policy” points to “Firewall policy identity-group membership does not include the authorized account.”; confirm this explanation by checking “Compare the local user's membership against the selected policy user group.” rather than changing an unrelated feature.
Incorrect Answers
A:“The local-user object is disabled while its group and policy references remain intact” would support “The local account is administratively disabled.”, but the incident records “The local user is absent from the user group referenced by the applicable policy”, a different clue pointing to “Firewall policy identity-group membership does not include the authorized account.”.
B:The proposed fault “The FortiGate and RADIUS server no longer share the same secret.” should be investigated if “RADIUS requests arrive at the server but authentication processing reports an invalid authenticator”; here the evidence is “The local user is absent from the user group referenced by the applicable policy”, which supports “Firewall policy identity-group membership does not include the authorized account.”.
C:“Inspect returned RADIUS attributes and the configured remote-group match conditions.” tests the alternate scenario “RADIUS group authorization attributes do not align with the FortiGate group mapping.” associated with “The Access-Accept does not contain the vendor/group attribute required by the FortiGate matching rule”; this ticket instead has “The local user is absent from the user group referenced by the applicable policy”.
E:The competing explanation “RADIUS transport is blocked or misrouted between FortiGate and the server.” depends on “Packets from the FortiGate to the authentication server's configured UDP port receive no response”, whereas the established finding “The local user is absent from the user group referenced by the applicable policy” implicates “Firewall policy identity-group membership does not include the authorized account.”.
Question 771
A FortiGate has this symptom: An appliance becomes slow after many administrative diagnostic sessions are left running. Investigation finds: A process listing shows multiple intensive diagnostic operations consuming measurable CPU. Which sequence checks the fault before remediation?
- Check: Inspect hardware sensor and fan status in addition to process utilization; then correct: repair the failing cooling component and restore safe environmental conditions.
- Check: Review process utilization alongside open diagnostic sessions and planned captures; then correct: stop unnecessary diagnostic collection and rerun targeted captures only.
- Check: Compare session totals, limits, and top session-producing hosts during the burst; then correct: find abnormal session generators and reduce excessive session churn or scale the platform.
- Check: Check disk utilization and local logging destination health rather than assuming traffic is denied; then correct: apply a safe retention or forwarding plan to restore capacity for local log writes.
Explanation
Correct Answer
B:Before making “Stop unnecessary diagnostic collection and rerun targeted captures only.”, use “Review process utilization alongside open diagnostic sessions and planned captures.” to substantiate the recorded “A process listing shows multiple intensive diagnostic operations consuming measurable CPU”; the closing check is “Baseline CPU returns after excessive diagnostic workloads are stopped.”.
Incorrect Answers
A:“Repair the failing cooling component and restore safe environmental conditions.” is the remedy for “A cooling hardware condition is driving thermal stress.” after “Inspect hardware sensor and fan status in addition to process utilization.”; the present fault instead requires confirming “Review process utilization alongside open diagnostic sessions and planned captures.” before “Stop unnecessary diagnostic collection and rerun targeted captures only.”.
C:The sequence “Compare session totals, limits, and top session-producing hosts during the burst.”, then “Find abnormal session generators and reduce excessive session churn or scale the platform.” fits the alternate evidence “The system's concurrent session count reaches its platform capacity during bursts”; the observed “A process listing shows multiple intensive diagnostic operations consuming measurable CPU” calls for “Review process utilization alongside open diagnostic sessions and planned captures.” and “Stop unnecessary diagnostic collection and rerun targeted captures only.”.
D:“Disk utilization reports a full logging partition and new local log writes fail” would justify testing “Check disk utilization and local logging destination health rather than assuming traffic is denied.” before “Apply a safe retention or forwarding plan to restore capacity for local log writes.”; here “A process listing shows multiple intensive diagnostic operations consuming measurable CPU” supports a different diagnosis-and-repair pair.
Question 772
The affected FortiGate has this verified defect: The device cannot resolve the next-hop Layer 2 address. Which repair is most closely aligned to that defect?
- Update the VIP mapped IP and verify matching policy and routing to the real server.
- Restore reachability to the correct DNS resolver and confirm valid responses.
- Correct the upstream VLAN, switch forwarding, or client gateway so packets reach the expected FortiGate ingress interface.
- Repair VLAN tagging, switching, or gateway reachability that prevents ARP replies.
Explanation
Correct Answer
D:Repair the mechanism “The device cannot resolve the next-hop Layer 2 address.” with “Repair VLAN tagging, switching, or gateway reachability that prevents ARP replies.”; doing so addresses “ARP resolution for the gateway stays incomplete despite an installed connected route”, but still requires “ARP resolves to the proper MAC and routed packets reach the adjacent gateway.” as proof of recovery.
Incorrect Answers
A:The proposed repair “Update the VIP mapped IP and verify matching policy and routing to the real server.” is tied to “Destination NAT points at the wrong private target.”, not the ticket clue “ARP resolution for the gateway stays incomplete despite an installed connected route”; apply “Repair VLAN tagging, switching, or gateway reachability that prevents ARP replies.” to the verified mechanism.
B:“The client DNS requests time out before any application-layer connection is attempted” would justify changing “Restore reachability to the correct DNS resolver and confirm valid responses.”; the present evidence “ARP resolution for the gateway stays incomplete despite an installed connected route” instead identifies “The device cannot resolve the next-hop Layer 2 address.” as the change target.
C:This action would fix “The fault lies before traffic reaches the FortiGate ingress path.” when “A sniffer on the ingress interface sees no SYN packet from the client during the test”, but it leaves the documented “The device cannot resolve the next-hop Layer 2 address.” condition without its targeted “Repair VLAN tagging, switching, or gateway reachability that prevents ARP replies.” correction.
Question 773
An escalation includes this evidence: The next-hop address is not reachable through the selected interface's connected network or recursive resolution. The customer symptom is: A configured static route to an off-link gateway cannot be installed properly. What condition is causing the failure?
- The configured static next hop is unresolved.
- Administrative distance dominates priority when equal-length routes come from different sources.
- The static route is ineligible because its required interface is unavailable.
- The policy route is steering the traffic independently of the expected static route.
- Unequal static-route selection attributes prevent the intended ECMP behavior.
Explanation
Correct Answer
A:The observed “The next-hop address is not reachable through the selected interface's connected network or recursive resolution” points to “The configured static next hop is unresolved.”; confirm this explanation by checking “Use route lookup to verify reachability of the gateway address itself.” rather than changing an unrelated feature.
Incorrect Answers
B:“The competing routes have different administrative distances and the selected route has the lower distance” would support “Administrative distance dominates priority when equal-length routes come from different sources.”, but the incident records “The next-hop address is not reachable through the selected interface's connected network or recursive resolution”, a different clue pointing to “The configured static next hop is unresolved.”.
C:The proposed fault “The static route is ineligible because its required interface is unavailable.” should be investigated if “The route's egress interface is administratively down”; here the evidence is “The next-hop address is not reachable through the selected interface's connected network or recursive resolution”, which supports “The configured static next hop is unresolved.”.
D:“Inspect policy-route matches for the exact source and destination before editing static routes.” tests the alternate scenario “The policy route is steering the traffic independently of the expected static route.” associated with “A matching policy route selects a different egress path before ordinary destination routing”; this ticket instead has “The next-hop address is not reachable through the selected interface's connected network or recursive resolution”.
E:In the alternative case, “One path has a different distance or priority so the two entries are not equal candidates” explains “Unequal static-route selection attributes prevent the intended ECMP behavior.”; the observed “The next-hop address is not reachable through the selected interface's connected network or recursive resolution” makes the current diagnosis “The configured static next hop is unresolved.” more specific.
Question 774
After a change window, the support team reports: A browser accesses an HTTPS site over QUIC while expected HTTP inspection does not fire. An engineer independently verifies: Packet capture shows UDP 443 instead of the inspected TCP TLS flow. Which cause is supported by these observations?
- QUIC transport does not follow the expected TCP-based web inspection path.
- The URL filtering exemption scope is broader than the intended permission.
- Hostname visibility is insufficient for the selected lightweight HTTPS inspection method.
- The static URL filter pattern does not match the actual request URL.
Explanation
Correct Answer
A:For the failure signaled by “Packet capture shows UDP 443 instead of the inspected TCP TLS flow”, select “QUIC transport does not follow the expected TCP-based web inspection path.”; the direct follow-up check is “Capture UDP 443 and review application control or web-filter policy handling for QUIC.”, not a broad policy reset.
Incorrect Answers
B:In the alternative case, “The URL rule uses an exempt-type action where the design intended a narrower allow decision” explains “The URL filtering exemption scope is broader than the intended permission.”; the observed “Packet capture shows UDP 443 instead of the inspected TCP TLS flow” makes the current diagnosis “QUIC transport does not follow the expected TCP-based web inspection path.” more specific.
C:The competing explanation “Hostname visibility is insufficient for the selected lightweight HTTPS inspection method.” depends on “The flow provides no usable hostname information to certificate-only filtering at the decision point”, whereas the established finding “Packet capture shows UDP 443 instead of the inspected TCP TLS flow” implicates “QUIC transport does not follow the expected TCP-based web inspection path.”.
D:“The URL filter entry matches a different hostname variant than the one in the request” would support “The static URL filter pattern does not match the actual request URL.”, but the incident records “Packet capture shows UDP 443 instead of the inspected TCP TLS flow”, a different clue pointing to “QUIC transport does not follow the expected TCP-based web inspection path.”.
Question 775
During fault isolation, the following is observed: The RADIUS server emits Start records to its own database but does not forward accounting to the FortiGate RSSO listener. Operational symptom: A RADIUS accounting based SSO design sees successful logins but no FSSO users. What is the most defensible root-cause assessment?
- RADIUS accounting messages are not being delivered to the FSSO/RSSO collector.
- The FortiGate-to-Collector Agent session has not recovered.
- The Collector Agent cannot retrieve logon events from one domain controller.
- Collector-disconnect logon retention is shorter than the outage period.
Explanation
Correct Answer
A:The clue “The RADIUS server emits Start records to its own database but does not forward accounting to the FortiGate RSSO listener” makes “RADIUS accounting messages are not being delivered to the FSSO/RSSO collector.” the defensible finding, while “Capture RADIUS accounting packets on the configured FortiGate receiving interface.” provides an observation that can confirm or refute it.
Incorrect Answers
B:The proposed fault “The FortiGate-to-Collector Agent session has not recovered.” should be investigated if “FortiGate shows its Collector Agent connection as down although TCP reachability is available”; here the evidence is “The RADIUS server emits Start records to its own database but does not forward accounting to the FortiGate RSSO listener”, which supports “RADIUS accounting messages are not being delivered to the FSSO/RSSO collector.”.
C:“Compare per-DC event-collection status and Windows event-read failures.” tests the alternate scenario “The Collector Agent cannot retrieve logon events from one domain controller.” associated with “Collector status reports polling errors only for the affected DC while other controllers succeed”; this ticket instead has “The RADIUS server emits Start records to its own database but does not forward accounting to the FortiGate RSSO listener”.
D:In the alternative case, “The FortiGate's configured FSSO logon timeout expires during the collector disconnect” explains “Collector-disconnect logon retention is shorter than the outage period.”; the observed “The RADIUS server emits Start records to its own database but does not forward accounting to the FortiGate RSSO listener” makes the current diagnosis “RADIUS accounting messages are not being delivered to the FSSO/RSSO collector.” more specific.
Question 776
The support record reports Two equal-cost static paths are intended to carry connections but only one appears active and specifically observes One path has a different distance or priority so the two entries are not equal candidates. Which root cause and targeted fix explain it?
- Cause: The policy route is steering the traffic independently of the expected static route; correction: correct or narrow the matching policy route for the application traffic.
- Cause: SD-WAN service selection overrides the administrator's simplistic default-route expectation; correction: correct the matching SD-WAN service rule and health-criteria preference so the intended member is selected for the approved flow.
- Cause: The static route is ineligible because its required interface is unavailable; correction: restore the intended egress interface or install a valid alternate route.
- Cause: Unequal static-route selection attributes prevent the intended ECMP behavior; correction: align relevant route selection attributes and confirm both next hops are usable.
Explanation
Correct Answer
D:The incident clue “One path has a different distance or priority so the two entries are not equal candidates” supports “Unequal static-route selection attributes prevent the intended ECMP behavior.”; the matching change is “Align relevant route selection attributes and confirm both next hops are usable.”, and “Eligible equal-cost paths appear for the prefix and distribute new flows as designed.” provides objective closure.
Incorrect Answers
A:The alternative handoff pairs “The policy route is steering the traffic independently of the expected static route.” with “Correct or narrow the matching policy route for the application traffic.”; that matches “A matching policy route selects a different egress path before ordinary destination routing” rather than the reported “One path has a different distance or priority so the two entries are not equal candidates”.
B:“The matching SD-WAN service rule ranks the second member ahead for that flow” could warrant “Correct the matching SD-WAN service rule and health-criteria preference so the intended member is selected for the approved flow.” for “SD-WAN service selection overrides the administrator's simplistic default-route expectation.”, while this incident requires “Align relevant route selection attributes and confirm both next hops are usable.” for “Unequal static-route selection attributes prevent the intended ECMP behavior.”.
C:The proposed cause “The static route is ineligible because its required interface is unavailable.” is a different failure mode, evidenced by “The route's egress interface is administratively down”; the recorded clue is “One path has a different distance or priority so the two entries are not equal candidates”.
Question 777
A FortiGate has this symptom: A website rating occasionally times out and users receive inconsistent decisions. Investigation finds: The web filter log reports FortiGuard rating timeout events under high network latency. Which sequence checks the fault before remediation?
- Check: Correlate web filter
ftgd_err events with FortiGuard server latency and reachability; then correct: repair rating-service connectivity or adjust documented rating-error behavior within risk policy.
- Check: Capture UDP 443 and review application control or web-filter policy handling for QUIC; then correct: apply supported QUIC handling or protocol control so the required inspected path is used.
- Check: Examine URL filter action semantics and whether later inspection modules still run; then correct: replace the exemption with an appropriately constrained allow or category action after impact review.
- Check: Check the SSL/SSH inspection mode and whether the browser trusts the FortiGate CA; then correct: deploy appropriate deep inspection with client trust and privacy safeguards where full URL inspection is required.
- Check: Check the static URL filter result before investigating FortiGuard category rating; then correct: reconcile URL filter exceptions with the intended category policy and remove unintended allow entries.
Explanation
Correct Answer
A:“Correlate web filter ftgd_err events with FortiGuard server latency and reachability.” directly tests “Remote rating response latency is causing the web filtering error behavior.” in light of “The web filter log reports FortiGuard rating timeout events under high network latency”, and “Repair rating-service connectivity or adjust documented rating-error behavior within risk policy.” is its corresponding repair; confirm using “Rating queries complete or use the explicitly configured failure policy consistently.”.
Incorrect Answers
B:The proposed check “Capture UDP 443 and review application control or web-filter policy handling for QUIC.” investigates “QUIC transport does not follow the expected TCP-based web inspection path.”, not “Remote rating response latency is causing the web filtering error behavior.”, which is supported by “The web filter log reports FortiGuard rating timeout events under high network latency”.
C:“Replace the exemption with an appropriately constrained allow or category action after impact review.” is the remedy for “The URL filtering exemption scope is broader than the intended permission.” after “Examine URL filter action semantics and whether later inspection modules still run.”; the present fault instead requires confirming “Correlate web filter ftgd_err events with FortiGuard server latency and reachability.” before “Repair rating-service connectivity or adjust documented rating-error behavior within risk policy.”.
D:The other workflow targets “Certificate-only inspection cannot expose encrypted URL paths inside HTTPS content.”, evidenced by “The policy is using certificate inspection without a mechanism to inspect the encrypted request path”; the case being assessed reports “The web filter log reports FortiGuard rating timeout events under high network latency”.
E:The sequence “Check the static URL filter result before investigating FortiGuard category rating.”, then “Reconcile URL filter exceptions with the intended category policy and remove unintended allow entries.” fits the alternate evidence “The URL filter evaluated the explicit allow entry before FortiGuard category filtering”; the observed “The web filter log reports FortiGuard rating timeout events under high network latency” calls for “Correlate web filter ftgd_err events with FortiGuard server latency and reachability.” and “Repair rating-service connectivity or adjust documented rating-error behavior within risk policy.”.
Question 778
The on-call team needs a quick, focused data collection step. Symptom: The Collector Agent is online but one domain controller contributes no user logons. What should it inspect?
- Inspect collector monitored groups and the affected user's emitted group list.
- Check DC polling results and Windows event-log access errors.
- Compare per-DC event-collection status and Windows event-read failures.
- Review
config user fsso logon-timeout and the timing of the disconnect.
- Capture RADIUS accounting packets on the configured FortiGate receiving interface.
- Check
diagnose debug authd fsso server-status alongside Collector Agent service health.
Explanation
Correct Answer
C:Investigate “The Collector Agent is online but one domain controller contributes no user logons” with “Compare per-DC event-collection status and Windows event-read failures.” because it can establish whether “The Collector Agent cannot retrieve logon events from one domain controller.” is responsible for the observed behavior.
Incorrect Answers
A:For the alternative clue “The FSSO logon exists but the Collector Agent is not sending the group used by that firewall policy”, use “Inspect collector monitored groups and the affected user's emitted group list.”; for the present clue “Collector status reports polling errors only for the affected DC while other controllers succeed”, use “Compare per-DC event-collection status and Windows event-read failures.”.
B:The check “Check DC polling results and Windows event-log access errors.” tests “The FortiGate polling identity cannot read the necessary DC logon events.”, which would be indicated by “The polling account can reach the DC but lacks access to the required Windows security event information”; the actual ticket calls for “Compare per-DC event-collection status and Windows event-read failures.”.
D:Investigating “Collector-disconnect logon retention is shorter than the outage period.” using “Review config user fsso logon-timeout and the timing of the disconnect.” is appropriate for “The FortiGate's configured FSSO logon timeout expires during the collector disconnect”, not for the recorded “Collector status reports polling errors only for the affected DC while other controllers succeed”.
E:“Capture RADIUS accounting packets on the configured FortiGate receiving interface.” would validate the alternate mechanism “RADIUS accounting messages are not being delivered to the FSSO/RSSO collector.”; here “Collector status reports polling errors only for the affected DC while other controllers succeed” focuses the evidence collection on “The Collector Agent cannot retrieve logon events from one domain controller.”.
F:For the alternative clue “FortiGate shows its Collector Agent connection as down although TCP reachability is available”, use “Check diagnose debug authd fsso server-status alongside Collector Agent service health.”; for the present clue “Collector status reports polling errors only for the affected DC while other controllers succeed”, use “Compare per-DC event-collection status and Windows event-read failures.”.
Question 779
The diagnosed incident is: A multihop eBGP session does not establish even though the peer responds to ping. Evidence: The peers are not directly adjacent and the configured eBGP TTL or multihop allowance is insufficient. Which TWO entries belong in a recovery record: the specific corrective operation and its observable validation? Choose TWO.
- Validation: The routed TCP 179 connection forms over the intended multihop path.
- Repair: Configure the same approved BGP neighbor authentication password on both peers.
- Validation: The intended prefix becomes accepted and eligible for best-path evaluation.
- Repair: Update the outbound prefix-list policy narrowly to include the desired network.
- Correction: Configure the required eBGP multihop and validated source and route settings.
Explanation
Correct Answers
A:“The routed TCP 179 connection forms over the intended multihop path.” is the acceptance test for the known issue “The eBGP peering configuration assumes direct adjacency for a multihop path.”; after “Configure the required eBGP multihop and validated source and route settings.”, it proves service behavior changed in the intended way.
E:“The peers are not directly adjacent and the configured eBGP TTL or multihop allowance is insufficient” supports the fault “The eBGP peering configuration assumes direct adjacency for a multihop path.”, making “Configure the required eBGP multihop and validated source and route settings.” the pertinent repair; the record should pair it with “The routed TCP 179 connection forms over the intended multihop path.”.
Incorrect Answers
B:“The two peers use different BGP TCP MD5 authentication passwords” would justify “Configure the same approved BGP neighbor authentication password on both peers.”; the established clue “The peers are not directly adjacent and the configured eBGP TTL or multihop allowance is insufficient” requires a fix of “The eBGP peering configuration assumes direct adjacency for a multihop path.”.
C:The proposed closeout “The intended prefix becomes accepted and eligible for best-path evaluation.” validates “Inbound BGP policy filters the desired route before acceptance.”, not the known “The eBGP peering configuration assumes direct adjacency for a multihop path.” issue, for which “The routed TCP 179 connection forms over the intended multihop path.” is required.
D:The option proposes “Update the outbound prefix-list policy narrowly to include the desired network.” for “Outbound BGP filtering suppresses the approved advertisement.”, but “The peers are not directly adjacent and the configured eBGP TTL or multihop allowance is insufficient” points to “The eBGP peering configuration assumes direct adjacency for a multihop path.” and its corresponding “Configure the required eBGP multihop and validated source and route settings.” action.
Question 780
After a change window, the support team reports: Users authenticate successfully at RADIUS but do not match the expected FortiGate user group. An engineer independently verifies: The Access-Accept does not contain the vendor/group attribute required by the FortiGate matching rule. Which cause is supported by these observations?
- RADIUS group authorization attributes do not align with the FortiGate group mapping.
- Remote group matching is wrong even though password authentication works.
- The FortiGate and RADIUS server no longer share the same secret.
- The failure is an account password lifecycle condition, not connector reachability.
Explanation
Correct Answer
A:For the failure signaled by “The Access-Accept does not contain the vendor/group attribute required by the FortiGate matching rule”, select “RADIUS group authorization attributes do not align with the FortiGate group mapping.”; the direct follow-up check is “Inspect returned RADIUS attributes and the configured remote-group match conditions.”, not a broad policy reset.
Incorrect Answers
B:The proposed fault “Remote group matching is wrong even though password authentication works.” should be investigated if “LDAP authentication succeeds but the LDAP group returned does not match the FortiGate authorization group”; here the evidence is “The Access-Accept does not contain the vendor/group attribute required by the FortiGate matching rule”, which supports “RADIUS group authorization attributes do not align with the FortiGate group mapping.”.
C:“Run a direct RADIUS authentication test and inspect server-side authenticator errors.” tests the alternate scenario “The FortiGate and RADIUS server no longer share the same secret.” associated with “RADIUS requests arrive at the server but authentication processing reports an invalid authenticator”; this ticket instead has “The Access-Accept does not contain the vendor/group attribute required by the FortiGate matching rule”.
D:In the alternative case, “The directory explicitly reports that the affected user's password has expired” explains “The failure is an account password lifecycle condition, not connector reachability.”; the observed “The Access-Accept does not contain the vendor/group attribute required by the FortiGate matching rule” makes the current diagnosis “RADIUS group authorization attributes do not align with the FortiGate group mapping.” more specific.